欢迎访问行业研究报告数据库

行业分类

当前位置:首页 > 报告详细信息

找到报告 1 篇 当前为第 1 页 共 1

在i-66中使用预制的板进行路面修复

Use of Precast Slabs for Pavement Rehabilitation on I-66 

作者:Hossain, M. S.Ozyildirim, C. 作者单位:Virginia Center for Transportation Innovation and Research, Charlottesville, VA.;Virginia Dept. of Transportation, Richmond.;Federal Highway Administration, Richmond, VA. Virginia Div. 加工时间:2014-02-22 信息来源:科技报告(PB) 索取原文[84 页]
关键词:路面;预制系统;混凝土;质量控制
摘 要:Highway agencies continuously strive to expedite pavement construction and repairs and to evaluate materials and methods to provide long-lasting pavements. As part of this effort, agencies have used precast concrete slabs for more than 10 years with successive improvements in processes and systems. The Virginia Department of Transportation recently used two precast systems along with conventional cast-in-place repairs on a section of jointed reinforced concrete pavement on I-66 near Washington, D.C. One precast system, precast concrete pavement (PCP), used doweled joints. The other precast system, prestressed precast concrete pavement (PPCP), used transversely prestressed slabs post-tensioned in the longitudinal direction. Both precast systems are performing satisfactorily after 1.5 years of traffic, and the contractor was satisfied with the constructability. In multiple locations, transverse expansion joints in PPCP were observed to be wider than the 12-in width specified; excessively wide joints often compromise joint sealant performance, and erosion from water flowing through such joints may result in eventual loss of support over time. There were a few cracks in the PPCP section, originating mainly from grouting holes, cracks in the block-out patches, cracks and loss of epoxy at lifting hook holes, and corner breaks. There were some mid-slab cracks in the PCP slabs immediately after opening to traffic, but they are still tight and stable after 1.5 years of traffic. Even though the precast slabs initially cost more than the cast-in-place repairs to construct, the ability to construct the pavement within a short period of lane closure per day and the probability of improved quality control of plant-cast concrete warrant their use. Since this was the first application in Virginia, certain issues occurred and most were overcome, such as matching of slabs and grout leakage. The project was successfully completed and further implementation is recommended.
© 2016 武汉世讯达文化传播有限责任公司 版权所有 技术支持:武汉中网维优
客服中心

QQ咨询


点击这里给我发消息 客服员


电话咨询


027-87841330


微信公众号




展开客服