关键词:腐蚀;不锈钢;高压蒸汽灭菌器;盐水
摘 要:Severe localized corrosion of a 316 stainless steel autoclave occurred during investigating Type H Portland cement stability in 0.16 M CaCl(sub 2) + 0.02 M MgCl(sub 2) + 0.82 M NaCl brine in contact with supercritical CO(sub 2) containing 4O(sub 2). The system operated at 85 C and pressure of 29 MPa. However, no corrosion was observed in the same type of autoclave being exposed to the same environment, containing Type H Portland cement cylindrical samples, also operating at pressure of 29 MPa but at 50 C. The operation time for the 85 C autoclave was 53 days (1272 hours) while that for the 50 C autoclave was 66 days (1584 hours). Debris were collected from the base of both autoclaves and analyzed by X-ray diffraction (XRD). Corrosion products were only found in the debris from the 85 C autoclave. The cement samples were analyzed before and after the exposure by X-ray florescence (XRF) methods. Optical microscopy was used to estimate an extent of the 316 stainless steel corrosion degradation.